Hybrid wind tower systems
Kuaizhuang® Tower Joint Grout
- Primary search intent
- hybrid wind tower joint grout
- Best fit
- Prestressed ducts in hybrid wind towers
Hybrid wind tower systems
A two-component, thixotropic structural epoxy adhesive for horizontal and vertical joints between precast concrete segments in hybrid wind towers. The reviewed type-test evidence covers processing time, sag resistance, bond performance, compressive properties, shrinkage, glass-transition temperature and VOC-related items.

Recommended uses
Performance benefits
Technical data
“Requirement” is the stated acceptance threshold or range. “Actual result”, “typical value” and “published value” are not guaranteed minima unless the requirement column says so. Final acceptance must follow the approved TDS, report, test method and project conditions.
| Property | Minimum / specified requirement | Typical / reported value | Test method / source |
|---|---|---|---|
| Mix ratio by mass | — | Published valueA:B = 3:1 | Supplied product manual and type-test sample information |
| Packaging | — | Published valueComponent A 9 kg + component B 3 kg | Packaging format confirmed from the supplied A/B pail reference |
| Application / bonding time | ≥20 / ≥60 min | Actual result32 / 90 min | Independent type test; GB/T 44543-2024 |
| Sag resistance | ≥10 mm | Actual result14 mm | Independent type test |
| Compressive strength | ≥80 MPa | Actual result146.2 MPa | Independent type test; method-specific result |
| Instantaneous / 1-hour delayed compressive modulus | ≥8,000 / ≥6,000 MPa | Actual result13,365.5 / 8,158.1 MPa | Independent type test |
| Tensile strength | ≥30 MPa | Actual result40.2 MPa | Independent type test |
| Elongation at break | ≥0.3% | Actual result0.35% | Independent type test |
| Concrete-to-concrete flexural bond | Concrete substrate failure | Actual resultConcrete substrate failure | Independent type test |
| Concrete-to-concrete compression shear | ≥14 MPa | Actual result21.0 MPa | Independent type test |
| Steel-to-steel tensile shear | ≥17 MPa | Actual result20.0 MPa | Independent type test |
| Steel-to-concrete pull-off bond | ≥3.0 MPa and concrete failure | Actual result3.6 MPa and concrete substrate failure | Independent type test |
| Glass-transition temperature | ≥60°C | Actual result76.7°C | Independent type test |
| Shrinkage | ≤0.1% | Actual result0.04% | Independent type test |
| Non-volatile content | ≥99% | Actual result99.7% | Independent type test |
| VOC | ≤100 g/kg | Actual result8 g/kg | Independent type test |
Project approval input
A technical recommendation is only as reliable as the project information supplied with the enquiry.
Foundation, annulus, segment joint, duct or blade bond-line drawing.
Gap, section, lift height, net material volume and contingency.
Strength ages, flow, modulus, bond, fatigue, durability and test methods.
Material, water, substrate and ambient temperature plus exposure conditions.
Mixer output, pump, hose diameter, distance, access and standby capacity.
Batch cycle, working time, continuous-placement plan, curing and release point.
English technical data sheet
Prepared from the supplied Sino-sina Building Materials Co., Ltd. product manual. Requirements are kept separate from published or reported values. Use the current controlled document and project specification for final approval.
Independent test evidence
Values in the reported-result column were transcribed from independent laboratory reports supplied by Sino-sina. Public material retains Sino-sina Building Materials Co., Ltd. and, where positively verified, the testing institution and report reference; project/client identities, personnel, signatures, stamps, QR codes and contact addresses are omitted.
Photographed field method
The photographs show the adhesive pail, serrated-trowel application, a continuous ridge pattern and segment lifting. Product ratio, working time, joint temperature, coverage and final squeeze-out remain controlled inspection points.
Open the adhesive application guide


Product packaging
No Chinese product-manual page is displayed on this website. Technical acceptance remains subject to the current approved English TDS and privacy-protected evidence.

Related materials
Hybrid wind tower systems
Technical enquiry
Include the wind structure and connection drawing, geometry or bond line, volume, specified performance, temperature, standards, installation window and equipment.