A high-flow cementitious pressure grout for prestressed ducts, connection voids and segment-related grouting in precast and hybrid wind towers. The technical positioning focuses on flow time, zero bleeding, expansion, compressive strength and flexural strength.

Recommended uses
Performance benefits
Technical data
“Requirement” is the stated acceptance threshold or range. “Actual result”, “typical value” and “published value” are not guaranteed minima unless the requirement column says so. Final acceptance must follow the approved TDS, report, test method and project conditions.
| Property | Minimum / specified requirement | Typical / reported value | Test method / source |
|---|---|---|---|
| Water-to-material ratio | 0.26-0.28 maximum route | — | Supplied Chinese product manual; confirm by approved TDS |
| Initial / final setting time | ≥5 h / ≤24 h | — | Supplied Chinese product manual |
| Flow time - initial / 30 / 60 min | 10-17 / 10-20 / 10-25 s | — | Supplied Chinese product manual |
| 3-hour bleeding / filament bleeding | 0% / 0% | — | Supplied Chinese product manual |
| Pressure bleeding at 0.22 or 0.36 MPa | ≤2.0% | — | Supplied Chinese product manual |
| Free expansion - 3 / 24 hours | 0-2% / 0-3% | — | Supplied Chinese product manual |
| Compressive strength - 3 / 7 / 28 days | ≥25 / ≥35 / ≥80 MPa | — | Supplied Chinese product manual |
| Flexural strength - 3 / 7 / 28 days | ≥5 / ≥6 / ≥10 MPa | — | Supplied Chinese product manual |
Project approval input
A technical recommendation is only as reliable as the project information supplied with the enquiry.
Foundation, annulus, segment joint, duct or blade bond-line drawing.
Gap, section, lift height, net material volume and contingency.
Strength ages, flow, modulus, bond, fatigue, durability and test methods.
Material, water, substrate and ambient temperature plus exposure conditions.
Mixer output, pump, hose diameter, distance, access and standby capacity.
Batch cycle, working time, continuous-placement plan, curing and release point.